Home / MS parts / NSN 5925-00-894-8015
NSN 5925-00-894-8015  ·  NIIN 008948015  ·  FSC 5925
NO DASHES 5925008948015
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

31 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CMLPTHREAD QUANTITY PER INCH32
AKPXPOLE QUANTITY1
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 0.625
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 1.566 AND INCHES MAXIMUM 1.582
AFJNFRAGILITY FACTORMODERATELY RUGGED
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
ADAQBODY LENGTHINCHES NOMINAL 2.000
ADATBODY WIDTHINCHES NOMINAL 1.813
ADAUBODY HEIGHTINCHES MAXIMUM 1.875
AAQLBODY STYLE
CRCFTRIP RELEASE AMBIENT TEMP RATINGSINGLE LOCATION CELSIUS NOMINAL 25.0
MATTMATERIALCASE PLASTIC
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 15.0
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 8.000 AND MAXIMUM AT 200 PCT 50.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDWATERPROOF AND VIBRATION RESISTANT AND SHOCK RESISTANT AND SALT SPRAY PROOF AND FUNGUS RESISTANT
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CPRJTRIP RELEASE METHODSINGLE LOCATION THERMAL
TTQYTERMINAL TYPE AND QUANTITYQUICK DISCONNECT, FEMALE 2
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH BUTTON 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CQJXNOMINAL THREAD SIZEINCHES 0.164
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION DC 28.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION DC 575.0
CPRQRESET METHODMANUAL

Supersedes

This item replaces cancelled NIINs 007401949 · 009381000. An older drawing citing one of those numbers resolves here.