NSN 3010-00-993-5246 · NIIN 009935246 · FSC 3010
NO DASHES 3010009935246
In Stock
GEARCASE-MOTOR
Torque Converters and Speed Changers
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| BFLT | TIME INTERVAL | MINUTES MINIMUM OFF 1.0 AND MINUTES MAXIMUM ON 9.0 |
| BFMF | COOLING METHOD | NONVENTILATED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | CLAMP COLLAR 1 |
| ANPZ | ENCLOSURE FEATURE | TOTALLY ENCLOSED |
| AXCP | WINDING TYPE | PERMANENT MAGNET |
| AXGY | MOUNTING METHOD | CLAMP RING(S) |
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | FEET 10000.0 |
| AKCT | SHAFT ROTATION DIRECTION | SINGLE END CLOCKWISE |
| CWDY | TEMP RATING | OPERATING CELSIUS -28.0 AND OPERATING CELSIUS 65.0 |
| CWGL | CURRENT RATING IN AMPS | OUTPUT SINGLE 0.370 |
| AAJU | OVERALL LENGTH | INCHES 5.000 |
| AAJV | OVERALL WIDTH | INCHES 1.250 |
| ABWV | SHAFT DIAMETER | SINGLE END INCHES MINIMUM 0.249 AND INCHES MAXIMUM 0.250 |
| ACDC | CURRENT TYPE | INPUT DC |
| CWHZ | SHAFT END CHARACTERISTIC | SINGLE END SINGLE STYLE A1 |
| TTQY | TERMINAL TYPE AND QUANTITY | SCREW 2 |
| BKPB | CURRENT RATING METHOD | LOAD |
| BKPQ | INCLOSURE SPECIFICATION | COMMERCIAL |
| CBBL | FEATURES PROVIDED | VERTICAL MOUNTING POSITION AND ELECTRIC NOISE SUPPRESSOR AND HORIZONTAL MOUNTING POSITION |
| BFLY | GEARED HEAD OUTPUT SHAFT ALIGNMENT POSITION | SINGLE END INLINE W/ARMATURE |
| CNXS | POWER RATING | OUTPUT HORSEPOWER 0.0050 |
| CWCS | LENGTH OF SHAFT FROM HOUSING | SINGLE END INCHES 0.500 |
| CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | INPUT LINE TO NEUTRAL SINGLE 26.0 |
| CWHK | GEARED HEAD OUTPUT SHAFT SPEED RATING | SINGLE END FIRST MULTIPLE REVOLUTIONS PER MINUTE 39.000 AND SECOND MULTIPLE REVOLUTIONS PER MINUTE 47.000 |
| CWHR | ANGLE OF SHAFT TO MOUNTING BASE | SINGLE END DEGREES 90.0 |
| AKPS | DUTY CYCLE | INTERMITTENT |
Supersedes
This item replaces cancelled NIIN 009465110. An older drawing citing one of those numbers resolves here.