NSN 6665-01-691-0255 · NIIN 016910255 · FSC 6665
NO DASHES 6665016910255
In Stock
DETECTOR,GAS
Hazard-Detecting Instruments and Apparatus
Technical characteristics
9 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABKW | OVERALL HEIGHT | MILLIMETERS NOMINAL 10.0 |
| CXCY | PART NAME ASSIGNED BY CONTROLLING AGENCY | 1 LEL 75C COMBUSTIBLE GAS SENSOR |
| SPCL | SPECIAL TEST FEATURES | SAFETY NOTE-THIS SENSOR IS DESIGNED TO BE USED IN SAFETY-CRITICAL APPLICATIONS. TO ENSURE THAT THE SENSOR AND/OR INSTRUMENT IN WHICH IT IS USED, ARE OPERATING PROPERLY, IT IS A REQUIREMENT THAT THE FUNCTION OF THE DEVICE IS CONFIRMED BY EXPOSURE TO TARGET GAS (BUMP CHECK) BEFORE EACH USE OF THE SENSOR AND/OR INSTRUMENT. FAILURE TO CARRY OUT SUCH TESTS MAY JEOPARDIZE THE SAFETY OF PEOPLE AND PROPERTY. |
| ABMK | OVERALL WIDTH | MILLIMETERS NOMINAL 20.3 |
| FEAT | SPECIAL FEATURES | ROHS COMPLIANT; NOMINAL RANGE: 0.0 TO 1000.0 PERCENT LEL; INBOARD FILTER: REMOVE H2S; INBOARD FILTER CAPACITY: 1000.0 PPM HR MIN; ADDITIONAL FILTER: SILICA FILTER TO IMPROVE SILICONE RESISTANCE; OPERATING CURRENT: 84 MA MAX; POWER REQUIREMENT: 280 MW MAX; OPERATING TEMPERATURE: -40 DEGREES C TO 60 DEGREES C; STORAGE TEMPERATURE: 0 DEGREES C TO 20 DEGREES C IN SEALED CONTAINER; STORAGE LIFE: 6 MONTHS IN ORIGINAL PACKAGING; OPERATING LIFE: 5 YEARS IN AIR. |
| MATT | MATERIAL | CASE PLASTIC |
| ABHP | OVERALL LENGTH | MILLIMETERS NOMINAL 20.3 |
| AMRX | DETECTING ELEMENT TYPE | GEIGER TUBE |
| AMSE | VOLTAGE RATING | KILOVOLTS NOMINAL 3.3 |