| MRC | Requirement | Value |
|---|---|---|
| AAQL | BODY STYLE | |
| ABHP | OVERALL LENGTH | INCHES MINIMUM 1.990 AND INCHES MAXIMUM 2.010 |
| ABKW | OVERALL HEIGHT | INCHES MINIMUM 1.365 AND INCHES MAXIMUM 1.385 |
| ABMK | OVERALL WIDTH | INCHES MINIMUM 1.740 AND INCHES MAXIMUM 1.760 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES MINIMUM 0.210 AND INCHES MAXIMUM 0.230 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AKPX | POLE QUANTITY | 2 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | TERMINAL 2 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BBRJ | SPECIAL HANDLING FEATURE | MAGNETIC |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES DC 50.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS DC 24.0 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS DC 1000.0 |
| CPRH | CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| CPRJ | TRIP RELEASE METHOD | ALL LOCATIONS THERMAL |
| CPRL | TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS INSTANTANEOUS |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| CPRQ | RESET METHOD | AUTOMATIC |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | ALL LOCATIONS SERIES TRIP |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | HERMETICALLY SEALED |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | ALL LOCATIONS CELSIUS NOMINAL 25.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 4 |