NSN 6115-01-234-5860 · NIIN 012345860 · FSC 6115
NO DASHES 6115012345860
In Stock
GENERATOR,ALTERNATING CURRENT
Generators and Generator Sets, Electrical
Technical characteristics
18 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AKCT | SHAFT ROTATION DIRECTION | SINGLE END COUNTERCLOCKWISE |
| AKPS | DUTY CYCLE | CONTINUOUS |
| ANPZ | ENCLOSURE FEATURE | TOTALLY ENCLOSED |
| ANTN | SPECIFIC USE | AIRBORNE GENERATOR |
| AXGY | MOUNTING METHOD | FLANGE |
| AYHE | EXCITOR TYPE | SELF-EXCITED |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BFMF | COOLING METHOD | OIL |
| BYDT | BEARING TYPE | ANNULAR BALL |
| CNXS | POWER RATING | OUTPUT KILOWATTS 45.000 |
| CWDY | TEMP RATING | OPERATING FAHRENHEIT -65.0 AND OPERATING FAHRENHEIT 250.0 |
| CWFX | ROTOR SPEED RATING IN RPM | SINGLE FULL LOAD 12000.0 |
| CWGL | CURRENT RATING IN AMPS | OUTPUT SINGLE 174.000 |
| CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | OUTPUT LINE TO NEUTRAL SINGLE 115.0 OR LINE TO LINE SINGLE 200.0 |
| FAAZ | PHASE | OUTPUT THREE |
| FEAT | SPECIAL FEATURES | THE GENERATOR WILL BE MATED WITH A MCAIR PS 68-790053 CONSTANT SPEED DRIVE;THE MATED DRIVE AND GENERATOR SHALL COMPRISE THE EQUIPMENT DESIGNATED ASTHE INTEGRATED DRIVE GENERATOR;SUPPORTROTOR AT DRIVE END DURING STORAGE AND ASSEMBLY TO PREVENT DAMAGE TO ROTOR AND STATOR |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | BINDING POST 4 |