NSN 6125-00-110-4150 · NIIN 001104150 · FSC 6125
NO DASHES 6125001104150
In Stock
MOTOR-GENERATOR
Converters, Electrical, Rotating
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AKAE | MAXIMUM OPERATING ALTITUDE RATING | FEET 65000.0 |
| AKPS | DUTY CYCLE | CONTINUOUS |
| AAJT | OVERALL HEIGHT | INCHES 9.625 |
| AAJU | OVERALL LENGTH | INCHES 13.156 |
| AAJV | OVERALL WIDTH | INCHES 7.125 |
| ACDC | CURRENT TYPE | INPUT DC |
| ANPZ | ENCLOSURE FEATURE | TOTALLY ENCLOSED |
| AXGY | MOUNTING METHOD | FIXED BASE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 4 AND SLOT 2 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| BFMF | COOLING METHOD | FAN COOLED |
| BKPQ | INCLOSURE SPECIFICATION | MIL-STD-108 |
| CBBL | FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION |
| CNXS | POWER RATING | OUTPUT WATTS 2250.0 |
| CWDT | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | INCHES 9.000 |
| CWDY | TEMP RATING | OPERATING CELSIUS -55.0 AND OPERATING CELSIUS 85.0 |
| CWFY | NOMINAL CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | INCHES 6.000 |
| CWGL | CURRENT RATING IN AMPS | INPUT SINGLE 165.000 |
| CWGQ | CONNECTION TYPE AND VOLTAGE RATING IN VOLTS | INPUT LINE TO NEUTRAL SINGLE 28.0 |
| FAAZ | PHASE | OUTPUT SINGLE OR THREE |
| FEAT | SPECIAL FEATURES | TYPE 32B161-1 INVERTER WILL FIT ALL APPLICATIONS WHERE DWG.MS16062 AND SPEC. MIL-1-7032D ARE CALLED OUT |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| TTQY | TERMINAL TYPE AND QUANTITY | SOLDERLESS LUG 6 |