Home / MS parts / NSN 5985-00-655-1204
NSN 5985-00-655-1204  ·  NIIN 006551204  ·  FSC 5985
NO DASHES 5985006551204
In Stock

SWITCH,WAVEGUIDE

Antennas, Waveguides, and Related Equipment

Technical characteristics

36 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CSQTFLANGE CONNECTING FACILITY AND QUANTITYUNTHREADED HOLE(S) 4
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 3
MATTMATERIALBODY ALUMINUM ALLOY
THSDTHREAD SERIES DESIGNATORMOUNTING FACILITY HOLE UNIFIED NATIONAL COARSE (UNC)
TTQYTERMINAL TYPE AND QUANTITYSCREW 4 AND CIRCULAR FLANGE 3
AKRCCOUPLING POSITION QUANTITY3
ABMKOVERALL WIDTHINCHES NOMINAL 1.856
ACZBFREQUENCY RATINGSINGLE FREQUENCY CROSSTALK REFERENCE GIGAHERTZ MINIMUM 16.20 AND GIGAHERTZ MAXIMUM 16.83
ACZBFREQUENCY RATINGSINGLE FREQUENCY INSERTION LOSS REFERENCE GIGAHERTZ MINIMUM 16.20 AND GIGAHERTZ MAXIMUM 16.83
ACZBFREQUENCY RATINGSINGLE FREQUENCY OPERATING GIGAHERTZ MINIMUM 16.20 AND GIGAHERTZ MAXIMUM 16.83
ACZBFREQUENCY RATINGSINGLE FREQUENCY RF POWER HANDLING GIGAHERTZ MINIMUM 16.20 AND GIGAHERTZ MAXIMUM 16.83
ACZBFREQUENCY RATINGSINGLE FREQUENCY VOLTAGE STANDING WAVE RATIO GIGAHERTZ MINIMUM 16.20 AND GIGAHERTZ MAXIMUM 16.83
AEEASWITCH TYPETRANSFER
AFDSLONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES MINIMUM 1.641 AND INCHES MAXIMUM 1.651
AFDTSHORTEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES MINIMUM 0.818 AND INCHES MAXIMUM 0.828
FEATSPECIAL FEATURESCRITICAL APPLICATION FOR WEAPONS SYSTEM
ABKWOVERALL HEIGHTINCHES NOMINAL 1.856
AKNVMINIMUM CROSSTALK RATING IN DECIBELS45.0
AKPCACTUATOR OPERATING METHODRELAY
AKPEACTUATOR CURRENT TYPE AND RATING IN AMPSDC MAXIMUM 1.4
AKPJACTUATOR VOLTAGE IN VOLTSMINIMUM 17.0 AND MAXIMUM 22.5
CBBLFEATURES PROVIDEDGROUNDED OFF CIRCUIT TERMINATION
CQJXNOMINAL THREAD SIZEMOUNTING FACILITY HOLE INCHES 0.164
CQYJMOUNTING FACILITY PATTERNSINGLE MOUNTING FACILITY PATTERN ISOSCELES TRIANGLE
CRTLCRITICALITY CODE JUSTIFICATIONFEAT
AKPTWAVEGUIDE FLANGE TYPECHOKE
AAQLBODY STYLE
ABHPOVERALL LENGTHINCHES MAXIMUM 3.200
AKNFRF POWER HANDLING CAPABILITYSINGLE KILOWATTS PEAK 85.0
AKPPSWITCHING TIMESECONDS 0.025
AFDVLONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERSSINGLE MOUNTING FACILITY PATTERN INCHES MINIMUM 1.420 AND INCHES MAXIMUM 1.430
AFGAOPERATING TEMP RANGECELSIUS -55.0 TO 71.0
AHTWVOLTAGE STANDING WAVE RATIO1.20
AHTXINSERTION LOSS IN DECIBELS0.25
AKPQSWITCH RETURN MECHANISM TYPEFAIL-SAFE
SFTTSURFACE TREATMENTBODY OUTSIDE SURFACES ENAMEL