NSN 6130-01-407-5312 · NIIN 014075312 · FSC 6130
NO DASHES 6130014075312
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Application: NEXT ASSEMBLY P/N 333009-000; USED ON AN/ALR-56M
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AGAV | END ITEM IDENTIFICATION | NEXT ASSEMBLY P/N 333009-000; USED ON AN/ALR-56M |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| APNX | INPUT VOLTAGE RATING | FIRST ALTERNATE OPERATING POWER RQMT DC VOLTS NOMINAL 135.0 |
| APNX | INPUT VOLTAGE RATING | SECOND ALTERNATE OPERATING POWER RQMT DC VOLTS NOMINAL 15.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT DC VOLTS NOMINAL -15.2 |
| APPA | OUTPUT VOLTAGE RATING | SEVENTH POWER OUTPUT DC VOLTS NOMINAL 15.0 |
| APPA | OUTPUT VOLTAGE RATING | EIGHTH POWER OUTPUT DC VOLTS NOMINAL 28.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT DC VOLTS NOMINAL -100.0 |
| APPA | OUTPUT VOLTAGE RATING | NINTH POWER OUTPUT DC VOLTS NOMINAL 48.0 |
| APPA | OUTPUT VOLTAGE RATING | SIXTH POWER OUTPUT DC VOLTS NOMINAL 6.0 |
| APPA | OUTPUT VOLTAGE RATING | FOURTH POWER OUTPUT DC VOLTS NOMINAL -5.2 |
| APPA | OUTPUT VOLTAGE RATING | THIRD POWER OUTPUT DC VOLTS NOMINAL -6.0 |
| APPA | OUTPUT VOLTAGE RATING | FIFTH POWER OUTPUT DC VOLTS NOMINAL 5.0 |
| CWKG | VENTILATION DESIGN TYPE | INTEGRAL BLOWER |
| FEAT | SPECIAL FEATURES | ELECTROSTATIC SENSITIVE DEVICE; CONTAINS OVERLOAD PROTECTION; OPERATINGLIFE 20,000 HOURS; THE 330454-105 REPLACES 330454-102 |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |