NSN 3424-01-442-0379 · NIIN 014420379 · FSC 3424
NO DASHES 3424014420379
In Stock
FURNACE,HEAT TREATING,ELECTRIC
Metal Heat Treating and Non-Thermal Treating Equipment
Technical characteristics
18 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAXX | MOUNTING TYPE | FLOOR |
| ABFF | FURNISHED ITEMS | EQUIPMENT FOR FLAME CURTAIN |
| ACDC | CURRENT TYPE | AC |
| ACZB | FREQUENCY RATING | HERTZ NOMINAL 60.0 |
| ADJT | INSIDE WIDTH | INCHES NOMINAL 24.000 |
| ADJU | INSIDE LENGTH | INCHES NOMINAL 36.000 |
| AEHZ | MAXIMUM OPERATING TEMP | FAHRENHEIT 2500.0 |
| AFGA | OPERATING TEMP RANGE | FAHRENHEIT 1400.0 TO 2500.0 |
| AFMQ | INSIDE HEIGHT | INCHES NOMINAL 18.000 |
| AKYD | ACCESSORY COMPONENTS AND QUANTITY | TEMPERATURE RECORDER 1, AIR OPERATED DOOR 1 |
| APGF | DESIGN TYPE | CONTROLLED ATMOSPHERE FULL MUFFLE OVEN |
| AZFX | TEMP CONTROL DEVICE TYPE | AUTOMATIC |
| CFSP | WATTAGE RATING IN KILOWATTS | 40.0 |
| CFSS | DOOR/OPENING LOCATION AND QUANTITY | DOOR IN FRONT,1 |
| CGSP | ACCESS OPERATION METHOD | AIR OPERATED DOOR WITH FOOT OPERATED CONTROL VALVE |
| ELEC | VOLTAGE IN VOLTS | 230.0 |
| FAAZ | PHASE | THREE |
| FEAT | SPECIAL FEATURES | ENDOTHERMIC; FURANCE SHALL BE INITALLY WIRED FOR 230 VOLTS, WITH ALL HARDWARE FURNISHED FOR FIELD CONVERSION TO 460 VOLTS;FLAME CURTAIN IS REQUIRED FOR FLAMMABLE ATMOSPHERES OVER 1400 DEG. F. PER NFPA 86C |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| BHSF-182436-1371 | 56189 |
| MIL-F-80079 | 81349 |
| JHTB-96-98-1014 | 13873 |