NSN 6110-00-669-6330 · NIIN 006696330 · FSC 6110
NO DASHES 6110006696330
In Stock
STARTER,MOTOR
Electrical Control Equipment
Technical characteristics
20 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AKPS | DUTY CYCLE | CONTINUOUS |
| AQZF | CONTROL TYPE | REMOTE |
| ALGC | MOUNTING CONFIGURATION | SIXTEEN 9/16 IN. DIA MTG HOLES IN 4 ROWS HOLES IN EACH ROW SPACED 2-1/2 IN. BY 15 IN. BY 2-1/2 IN. C TO C ROWS SPACED 3 IN BY 10-1/2 IN. BY 3 IN. C TO C. |
| ANRK | SWITCH FUNCTIONAL POSITIONS | ON AND OFF |
| ANDW | LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE |
| ANDX | AMBIENT TEMP | CELSIUS 50.0 |
| ANPZ | ENCLOSURE FEATURE | WATERTIGHT |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 17.750 |
| AFLW | ACTUATION METHOD | MAGNETIC |
| AGLD | PERFORMANCE TYPE | SEMIAUTOMATIC |
| CNXS | POWER RATING | HORSEPOWER 5.000 AND HORSEPOWER 7.500 |
| FEAT | SPECIAL FEATURES | 150/2000 FT LBS SHOCK TEST |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 20.531 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 27.406 |
| CBBL | FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
| ANCN | OPERATING VOLTAGE CHARACTERISTIC | REDUCED |
| ANCP | VOLTAGE REDUCTION METHOD | RESISTOR |
| ANDE | ACTUATOR VOLTAGE | DC 230.0 |
| AGUE | FUSE ACCOMMODATION QUANTITY | 2 |