NSN 5930-01-111-9972 · NIIN 011119972 · FSC 5930
NO DASHES 5930011119972
In Stock
SWITCH,THERMOSTATIC
Switches
Technical characteristics
21 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAJD | THREAD CLASS | 3A |
| ABPM | BODY DIAMETER | INCHES MAXIMUM 0.665 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 1.500 |
| AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
| ASDB | WIDTH ACROSS FLATS | INCHES NOMINAL 1.000 |
| AWTN | OPERATING TEMP RATING | FAHRENHEIT MAXIMUM 400.0 |
| AXGY | MOUNTING METHOD | THREADED BUSHING |
| CBBL | FEATURES PROVIDED | HERMETICALLY SEALED CASE |
| CMLP | THREAD QUANTITY PER INCH | 16 |
| CQGB | CONTACT ACTION STIMULUS | DECREASE |
| CQJX | NOMINAL THREAD SIZE | SINGLE THREADED BUSHING INCHES 0.750 |
| CRLD | NONPILE-UP CONTACT ARRANGEMENT | POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION 1 |
| CSCF | TERMINAL TYPE | CONNECTOR, RECEPTACLE |
| CTHF | CONTACT LOAD CURRENT RATING | FIRST VOLTAGE AMPERES RESISTIVE LOAD 2.0 AND AMPERES INDUCTIVE LOAD 1.5 AND MILLIAMPERES LAMP LOAD 500.0 |
| CTHF | CONTACT LOAD CURRENT RATING | SECOND VOLTAGE AMPERES RESISTIVE LOAD 2.0 AND AMPERES INDUCTIVE LOAD 1.0 AND AMPERES LAMP LOAD 1.0 |
| CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CTYX | CONTACT STIMULUS RATING | DIFFERENTIAL POINT MAXIMUM DEGREES FAHRENHEIT 7.00 AND ACTUATION POINT NOMINAL DEGREES FAHRENHEIT 310.00 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | FIRST VOLTAGE AC AT SEA LEVEL 115.0 |
| CTZB | CONTACT VOLTAGE RATING IN VOLTS | SECOND VOLTAGE DC AT SEA LEVEL 28.0 |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE THREADED BUSHING UNF |