NSN 5985-00-009-8075 · NIIN 000098075 · FSC 5985
NO DASHES 5985000098075
In Stock
SWITCH,RADIO FREQUENCY TRANSMISS
Antennas, Waveguides, and Related Equipment
Technical characteristics
33 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AKNF | RF POWER HANDLING CAPABILITY | SINGLE KILOWATTS PEAK 3.0 |
| AKNV | MINIMUM CROSSTALK RATING IN DECIBELS | 25.0 |
| AKPC | ACTUATOR OPERATING METHOD | RELAY |
| AKPE | ACTUATOR CURRENT TYPE AND RATING IN AMPS | DC MAXIMUM 0.1 |
| AKPJ | ACTUATOR VOLTAGE IN VOLTS | NOMINAL 26.0 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 4 |
| CQJX | NOMINAL THREAD SIZE | MOUNTING FACILITY HOLE INCHES 0.112 |
| CQYJ | MOUNTING FACILITY PATTERN | SINGLE MOUNTING FACILITY PATTERN FOUR POSITION RECTANGULAR |
| MATT | MATERIAL | BODY ALUMINUM |
| SFTT | SURFACE TREATMENT | BODY ALL SURFACES ENAMEL |
| AHUD | CONNECTOR END DESIGN | FEMALE |
| AKQA | RF MAXIMUM VOLTAGE RATING | KILOVOLTS PEAK 1.0 |
| AKRC | COUPLING POSITION QUANTITY | 3 |
| ACZB | FREQUENCY RATING | SINGLE FREQUENCY OPERATING MEGAHERTZ MINIMUM 0.0 AND GIGAHERTZ MAXIMUM 6.0 |
| AEEA | SWITCH TYPE | NONTRANSFER |
| AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | SINGLE MOUNTING FACILITY PATTERN INCHES NOMINAL 1.032 |
| AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | SINGLE MOUNTING FACILITY PATTERN INCHES NOMINAL 0.281 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 100.0 |
| AHTW | VOLTAGE STANDING WAVE RATIO | 1.30 |
| AKPQ | SWITCH RETURN MECHANISM TYPE | FAIL-SAFE |
| AKPX | POLE QUANTITY | 1 |
| AKPY | THROW QUANTITY | 2 |
| AAJD | THREAD CLASS | 2B |
| AAQL | BODY STYLE | |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 2.375 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 1.938 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 2.062 |
| AHTX | INSERTION LOSS IN DECIBELS | 0.30 |
| AHUC | COAXIAL CONNECTOR SERIES DESIGNATION | N |
| THSD | THREAD SERIES DESIGNATOR | MOUNTING FACILITY HOLE UNIFIED NATIONAL COARSE (UNC) |
| TTQY | TERMINAL TYPE AND QUANTITY | TURRET 2 AND RECEPTACLE, COAXIAL 3 |
| AKPN | SWITCH OPERATION SEQUENCE | BREAKS BEFORE MAKES |
| AKPP | SWITCHING TIME | MILLISECONDS 25.0 |