NSN 5950-01-211-6459 · NIIN 012116459 · FSC 5950
NO DASHES 5950012116459
In Stock
TRANSFORMER,POWER
Coils and Transformers
Application: OLIVER PERRY CLASS FFG, NIMITZ CLASS CVN, AIRCRAFT ELECTRICAL SERVICING STATIONS, TICONDEROGA CLASS CG (47), TARAWA CLASS LHA, WASP CLASS LHD, FORRESTAL CLASS CV, SPRUANCE CLASS DD (963)
Technical characteristics
15 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABTB | MOUNTING HOLE DIAMETER | SINGLE GROUP INCHES NOMINAL 0.188 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT SINGLE PHASE TO SINGLE PHASE |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.250 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 1.625 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 1.938 |
| AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.188 |
| AGAV | END ITEM IDENTIFICATION | OLIVER PERRY CLASS FFG, NIMITZ CLASS CVN, AIRCRAFT ELECTRICAL SERVICING STATIONS, TICONDEROGA CLASS CG (47), TARAWA CLASS LHA, WASP CLASS LHD, FORRESTAL CLASS CV, SPRUANCE CLASS DD (963) |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AKPV | MOUNTING FACILITY QUANTITY | 2 |
| AXGY | MOUNTING METHOD | SINGLE GROUP UNTHREADED HOLE(S) |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRTL | CRITICALITY CODE JUSTIFICATION | FEAT |
| FEAT | SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
| TTQY | TERMINAL TYPE AND QUANTITY | TAB, SOLDER LUG 5 |