NSN 5996-00-563-4102 · NIIN 005634102 · FSC 5996
NO DASHES 5996005634102
In Stock
AMPLIFIER,MAGNETIC
Amplifiers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AXGY | MOUNTING METHOD | SINGLE GROUP THREADED STUD(S) |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 2.687 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| THSD | THREAD SERIES DESIGNATOR | SINGLE GROUP UNF |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CQJX | NOMINAL THREAD SIZE | SINGLE GROUP INCHES 0.190 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 6.281 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 3.688 |
| AKPV | MOUNTING FACILITY QUANTITY | 4 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE HOOK 7 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 3.312 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 4.312 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 5.562 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| CRGS | DC RESISTANCE RATING IN OHMS | 880.000 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 120.00 |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 AND CONTROL 1 |
| CHTZ | SATURATION CURRENT RATING | MILLIAMPERES 94.0 |