Home / MS parts / NSN 5925-00-984-6125
NSN 5925-00-984-6125  ·  NIIN 009846125  ·  FSC 5925
NO DASHES 5925009846125
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

40 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 3.053 AND INCHES MAXIMUM 3.073
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC-HYDRAULIC
ADATBODY WIDTHINCHES MINIMUM 3.042 AND INCHES MAXIMUM 3.062
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
ADAQBODY LENGTHINCHES MINIMUM 3.709 AND INCHES MAXIMUM 3.729
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND MOISTURE RESISTANT
CTJSUNPACKAGED UNIT WEIGHTPOUNDS NOMINAL 1.850
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
PMLCPRECIOUS MATERIAL AND LOCATIONSILVER TER-INAL SURFACES
PRMTPRECIOUS MATERIALSILVER
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
CQJXNOMINAL THREAD SIZEINCHES 0.138
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 0.300 AND MAXIMUM AT 200 PCT 1.000
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
AJECBOSS HEIGHTINCHES MINIMUM 0.146 AND INCHES MAXIMUM 0.166
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 3.239
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
BBRJSPECIAL HANDLING FEATUREMAGNETIC
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 5.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 416.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 1300.0
AAQLBODY STYLE
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
CPRQRESET METHODMANUAL
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 6
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES MINIMUM 1.021 AND INCHES MAXIMUM 1.041
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.740 AND INCHES MAXIMUM 2.760
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES MINIMUM 1.021 AND INCHES MAXIMUM 1.041
AFJNFRAGILITY FACTORMODERATELY RUGGED
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 3