NSN 6130-01-061-8878 · NIIN 010618878 · FSC 6130
NO DASHES 6130010618878
In Stock
POWER SUPPLY
Converters, Electrical, Nonrotating
Technical characteristics
12 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 21.500 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 5.250 |
| ABMK | OVERALL WIDTH | INCHES NOMINAL 19.000 |
| AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
| APNX | INPUT VOLTAGE RATING | SINGLE OPERATING POWER RQMT AC VOLTS MINIMUM 105.0 AND AC VOLTS MAXIMUM 125.0 |
| APPA | OUTPUT VOLTAGE RATING | SECOND POWER OUTPUT AC VOLTS MINIMUM 0.0 AND AC VOLTS MAXIMUM 270.0 |
| APPA | OUTPUT VOLTAGE RATING | FIRST POWER OUTPUT AC VOLTS MINIMUM 0.0 AND AC VOLTS MAXIMUM 135.0 |
| APTQ | INPUT FREQUENCY RATING | SINGLE OPERATING POWER RQMT HERTZ MINIMUM 48.0 AND HERTZ MAXIMUM 65.0 |
| AYNH | OPERATING AMBIENT TEMP RANGE | CELSIUS 0.1 TO 55.0 |
| CBBL | FEATURES PROVIDED | INPUT FILTER |
| CWGH | OUTPUT CURRENT RATING | FIRST POWER OUTPUT AC AMPERES MINIMUM 1.3 AND AC AMPERES MAXIMUM 1.7 |
| CWGN | OUTPUT PHASE | SINGLE POWER OUTPUT SINGLE |