NSN 5950-01-267-3980 · NIIN 012673980 · FSC 5950
NO DASHES 5950012673980
In Stock
TRANSFORMER,POWER
Coils and Transformers
Technical characteristics
19 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 0.625 |
| ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | SINGLE MOUNTING FACILITY SINGLE CENTER GROUP INCHES NOMINAL 0.250 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 0.800 |
| ACZB | FREQUENCY RATING | SINGLE COMPONENT HERTZ NOMINAL 400.0 |
| ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE COMPONENT TWO PHASE TO THREE PHASE |
| ACZD | TRANSFORMER WINDING CONNECTION TYPE | SCOTT |
| ACZF | MAXIMUM TRANSFORMER POWER RATING | SINGLE COMPONENT VOLT-AMPERE 0.9 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 1.500 |
| ADAT | BODY WIDTH | INCHES NOMINAL 0.750 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 0.550 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 130.0 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXGY | MOUNTING METHOD | SINGLE GROUP TERMINAL |
| BPLC | WINDING FUNCTION AND QUANTITY | SINGLE COMPONENT PRIMARY 1 AND SECONDARY 1 |
| CRBZ | WINDING OPERATING CURRENT | SINGLE COMPONENT SINGLE SECONDARY MILLIAMPERES AC MAXIMUM 43.0 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE PRIMARY AC VOLTS NOMINAL 6.00 |
| CWJS | WINDING OPERATING VOLTAGE | SINGLE COMPONENT SINGLE SECONDARY AC VOLTS NOMINAL 11.80 |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 7 |