NSN 4140-00-222-1142 · NIIN 002221142 · FSC 4140
NO DASHES 4140002221142
In Stock
FAN,VANEAXIAL
Fans, Air Circulators, and Blower Equipment
Technical characteristics
24 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| SFTT | SURFACE TREATMENT | OVERALL PAINT |
| STYL | STYLE DESIGNATOR | |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | FLANGE 1 AND UNTHREADED HOLE(S) 4 |
| AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| MATT | MATERIAL | OVERALL ALUMINUM |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | AC 200.0 |
| CSYL | PRIME MOVER POWER RATING | HORSEPOWER 0.024 |
| FEAT | SPECIAL FEATURES | W/2.25 IN. SQ FLANGE W/HOLE EA CORNER AT DISCHARGE END OF VENTURI TUBE |
| AAYD | STAGE QUANTITY | 1 |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| ABRY | LENGTH | INCHES NOMINAL 1.468 |
| ADNK | FLOW DIRECTION | OUTWARD |
| CWLX | HOUSING INSIDE DIAMETER | INCHES NOMINAL 1.990 |
| CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| FAAZ | PHASE | THREE |
| AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | INCHES OF WATER (INH20) 0.0 |
| AKCV | DRIVE TYPE | DIRECT |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 11000.0 |
| AGBD | ELECTRICAL CONNECTION TYPE | WIRE LEAD |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF AND EXPLOSION PROOF AND HUMIDITY PROOF AND SALT SPRAY RESISTANT AND SHOCK PROOF AND VIBRATION PROOF |
| CQKX | AIR FLOW RATE | CUBIC FEET PER MINUTE MAXIMUM 32.0 |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
Cross-references
5 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 024041 | 82877 |
| A0-74449 | 82877 |
| AXIMAX2P-395JH | 82877 |
| 6094499-2 | 03640 |
| 6127180 | 03640 |