NSN 4140-00-812-5224 · NIIN 008125224 · FSC 4140
NO DASHES 4140008125224
In Stock
FAN,VANEAXIAL
Fans, Air Circulators, and Blower Equipment
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AKCV | DRIVE TYPE | DIRECT |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AAYD | STAGE QUANTITY | 1 |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| CWLX | HOUSING INSIDE DIAMETER | INCHES NOMINAL 1.891 |
| CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| FAAZ | PHASE | SINGLE |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| MATT | MATERIAL | OVERALL ALUMINUM |
| SFTT | SURFACE TREATMENT | OVERALL ENAMEL |
| STDC | SURFACE TREATMENT DOCUMENT AND CLASSIFICATION | OVERALL MIL SPEC SINGLE TREATMENT RESPONSE -IL-E-5557,TY 4 |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LUG(S) 3 AND UNTHREADED HOLE(S) 3 |
| AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | COUNTERCLOCKWISE |
| CQKX | AIR FLOW RATE | CUBIC FEET PER MINUTE NOMINAL 48.0 |
| ABRY | LENGTH | INCHES NOMINAL 1.470 |
| ADNK | FLOW DIRECTION | OUTWARD |
| ADZC | ENVIRONMENTAL PROTECTION | MOISTURE RESISTANT |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | CELSIUS 100.0 |
| AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 17000.0 |
| AGBD | ELECTRICAL CONNECTION TYPE | TERMINAL BLOCK |
| AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | INCHES OF WATER (INH20) 0.0 |
| STYL | STYLE DESIGNATOR | |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 06424-2653569-2 |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | AC 115.0 |
| CSYL | PRIME MOVER POWER RATING | WATTS 18.0 |