NSN 4320-01-180-0920 · NIIN 011800920 · FSC 4320
NO DASHES 4320011800920
In Stock
PUMP UNIT,CENTRIFUGAL
Power and Hand Pumps
Technical characteristics
27 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAXH | PRIME MOVER QUANTITY | 1 |
| AAXX | MOUNTING TYPE | BASE |
| AAYD | STAGE QUANTITY | 1 |
| AAYT | INTAKE CONNECTION QUANTITY | 1 |
| AAYU | INTAKE CONNECTION TYPE | THREADED INTERNAL |
| AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
| AAYW | DISCHARGE CONNECTION TYPE | THREADED INTERNAL |
| ACDC | CURRENT TYPE | AC |
| ACZV | COOLING MEDIUM | PRIME MOVER AIR |
| ADZC | ENVIRONMENTAL PROTECTION | DRIPPROOF |
| AENC | PUMP QUANTITY | 1 |
| AHYV | MAXIMUM DISCHARGE FLOW RATE | GALLONS PER MINUTE 8.0 |
| AHYW | DISCHARGE PRESSURE | POUNDS PER SQUARE INCH GAUGE (PSIG) 175.0 |
| AHYZ | OPERATING SPEED AT RATED CAPACITY | REVOLUTIONS PER MINUTE 1750.0 |
| AHZE | CENTRIFUGAL PUMP DESIGN | RADIAL FLOW |
| AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
| AHZG | CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AKNA | INCLOSURE TYPE | OPEN |
| AMPS | CURRENT RATING IN AMPS | 1.6 AND 0.8 |
| BFMF | COOLING METHOD | SELF VENTILATED |
| CSYL | PRIME MOVER POWER RATING | HORSEPOWER 0.250 |
| ELEC | VOLTAGE IN VOLTS | 15.0 AND 230.0 |
| FAAZ | PHASE | SINGLE |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| MATT | MATERIAL | PUMP BASIC IRON |
| MEDA | MEDIA FOR WHICH DESIGNED | LOCATION NOT OTHERWISE SPECIFIED WATER, FRESH |