NSN 4320-01-226-7108 · NIIN 012267108 · FSC 4320
NO DASHES 4320012267108
In Stock
PUMP UNIT,CENTRIFUGAL
Power and Hand Pumps
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAXH | PRIME MOVER QUANTITY | 1 |
| AAXX | MOUNTING TYPE | BASE |
| AAYD | STAGE QUANTITY | 1 |
| AAYT | INTAKE CONNECTION QUANTITY | 1 |
| AAYU | INTAKE CONNECTION TYPE | ROUND FLANGE |
| AAYV | DISCHARGE CONNECTION QUANTITY | 1 |
| AAYW | DISCHARGE CONNECTION TYPE | ROUND FLANGE |
| ACDC | CURRENT TYPE | AC |
| ACZV | COOLING MEDIUM | PRIME MOVER AIR |
| ADZC | ENVIRONMENTAL PROTECTION | FUNGUS PROOF |
| AENC | PUMP QUANTITY | 1 |
| AHYV | MAXIMUM DISCHARGE FLOW RATE | GALLONS PER MINUTE 35.0 |
| AHYX | TOTAL HEAD | FEET 139.000 |
| AHYZ | OPERATING SPEED AT RATED CAPACITY | REVOLUTIONS PER MINUTE 3500.0 |
| AHZE | CENTRIFUGAL PUMP DESIGN | MIXED FLOW |
| AHZF | CENTRIFUGAL PUMP IMPELLER QUANTITY | 1 |
| AHZG | CENTRIFUGAL PUMP IMPELLER SUCTION TYPE | SINGLE |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| BFMF | COOLING METHOD | AIR TO AIR COOLED |
| CSYL | PRIME MOVER POWER RATING | HORSEPOWER 5.000 |
| ELEC | VOLTAGE IN VOLTS | 440.0 |
| FAAZ | PHASE | THREE |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| MEDA | MEDIA FOR WHICH DESIGNED | LOCATION NOT OTHERWISE SPECIFIED WATER, FRESH |
| ZZZT | NONDEFINITIVE SPEC/STD DATA | TYPE 2 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 27846-D | 23515 |
| 1X1.25 TY N-2 NAV TY2 | 23515 |
| MIL-P-17840 | 81349 |