NSN 4140-00-137-2493 · NIIN 001372493 · FSC 4140
NO DASHES 4140001372493
In Stock
FAN,CENTRIFUGAL
Fans, Air Circulators, and Blower Equipment
Technical characteristics
23 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| MATT | MATERIAL | BLADE ALUMINUM ALLOY |
| FAAZ | PHASE | SINGLE |
| FREQ | FREQUENCY IN HERTZ | 50.0 AND 60.0 |
| CSYL | PRIME MOVER POWER RATING | HORSEPOWER 0.455 |
| CWLY | PRIME MOVER DRIVE SHAFT BEARING TYPE | BALL |
| CXCB | DISCHARGE DIRECTION | HORIZONTAL |
| ABRY | LENGTH | INCHES NOMINAL 9.938 |
| AEQC | OPERATING SPEED AT RATED CAPACITY IN RPM | 3110.0 |
| AGBD | ELECTRICAL CONNECTION TYPE | WIRE LEAD |
| AJLY | STATIC PRESSURE AT SPECIFIED AIR FLOW RATE | INCHES OF WATER (INH20) 0.0 |
| AKCV | DRIVE TYPE | DIRECT |
| AKDJ | PRIME MOVER TYPE | ELECTRIC MOTOR |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 12 |
| AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| ABGL | WIDTH | INCHES NOMINAL 5.875 |
| AAYD | STAGE QUANTITY | 2 |
| CQKX | AIR FLOW RATE | CUBIC FEET PER MINUTE NOMINAL 56.0 |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | AC 115.0 |
| SFTT | SURFACE TREATMENT | OVERALL ENAMEL |
| STYL | STYLE DESIGNATOR | |
| MATT | MATERIAL | HOUSING STEEL |
Supersedes
This item replaces cancelled NIIN 004535752. An older drawing citing one of those numbers resolves here.