NSN 4520-00-054-4716 · NIIN 000544716 · FSC 4520
NO DASHES 4520000544716
In Stock
HEATER,DUCT TYPE,PORTABLE
Space and Water Heating Equipment
Technical characteristics
30 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AAXX | MOUNTING TYPE | TRAILER |
| ABAM | HEAT MEDIUM TYPE | AIR |
| ABAQ | OUTLET POSITION | IN THE SAME DIRECTION |
| ABAW | HEAT OUTLET QUANTITY | 6 |
| ABAX | HEAT DELIVERY DIRECTION | HORIZONTAL |
| ABAY | HEAT DISCHARGE OUTLET TYPE | STATIONARY |
| ABAZ | HEAT DIRECTING DEVICE | FLEXIBLE DUCTS |
| ABBA | AIR CIRCULATION DEVICE | SQUIRREL CAGE BLOWER |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| ABBD | MAXIMUM AIR FLOW RATE | CUBIC FEET PER MINUTE 1073.0 |
| ABBE | CIRCULATED AIR TYPE | HEATED |
| ABFG | RADIO INTERFERENCE SUPPRESSION TYPE | ARMY, MIL-STD-461, RADIO SUPPRESSION |
| ABFH | FLUE CONNECTION LOCATION | TOP CENTER |
| ACDC | CURRENT TYPE | AC |
| AEJZ | DEPTH | INCHES NOMINAL 50.000 |
| AKDJ | PRIME MOVER TYPE | GASOLINE ENGINE |
| ALYC | OPERATING CONTROL TYPE | HAND SWITCH |
| BDXJ | HEATING ELEMENT TYPE | COMBUSTION CHAMBER |
| BLJC | IGNITION METHOD | ELECTRODE |
| CQTY | FUEL CONSUMPTION RATE PER HOUR | GALLONS 5.0 |
| CQXD | HEAT DELIVERY RATE | KILOGRAM-CALORIE 400000.0 |
| CRJT | INTEGRAL FUEL TANK CAPACITY | GALLONS 17.5 |
| CSGC | FUEL FEED METHOD | INTERNAL PUMP |
| ELEC | VOLTAGE IN VOLTS | 220.0 |
| FAAZ | PHASE | THREE |
| FEAT | SPECIAL FEATURES | DISCHARGE AIR RANGE 150 DEG TO 280 DEG F,HEATER CONFORMS TO MIL-H-4607,CLASS 1,AIR FORCE TRAILER TYPE MA-1 REQUIRED |
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| FUEL | FUEL TYPE | GASOLINE |
| HGTH | HEIGHT | INCHES NOMINAL 26.000 |
| NMBR | QUANTITY | 1 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| BT400-42-1 | 5RQL2 |
| MILH4607 | 81349 |
| BT400-42-1 | 90598 |