NSN 4520-00-720-0176 · NIIN 007200176 · FSC 4520
NO DASHES 4520007200176
In Stock
HEATER,DUCT TYPE,PORTABLE
Space and Water Heating Equipment
Technical characteristics
24 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ZZZT | NONDEFINITIVE SPEC/STD DATA | TYPE -C1 |
| ABBD | MAXIMUM AIR FLOW RATE | CUBIC FEET PER MINUTE 926.1 |
| ABBE | CIRCULATED AIR TYPE | HEATED |
| CRJT | INTEGRAL FUEL TANK CAPACITY | GALLONS 28.0 |
| CSGC | FUEL FEED METHOD | INTERNAL PUMP |
| RDAL | REFERENCE DATA AND LITERATURE | AF TO. 35E7-2-5-1 |
| ABBB | SPEED ADJUSTMENTS | SINGLE SPEED |
| FTLD | FUNCTIONAL DESCRIPTION | THE TYPES MC-1 AND MD-1 HEATERS ARE INTENDED FOR USE IN THE HEATING OF AIRCRAFT COMPARTMENTS BY DELIVERY OF HEATED AIR AT MODERATE PRESSURES THROUGH AN AIRBORNE DUCT SYSTEM |
| FUEL | FUEL TYPE | 80/87 OCTANE GASOLINE AND 91/96 OCTANE GASOLINE AND 100/130 OCTANE GASOLINE AND 115/145 OCTANE GASOLINE |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-H-26934B |
| NMBR | QUANTITY | 1 |
| BLJC | IGNITION METHOD | ELECTRODE |
| CQTY | FUEL CONSUMPTION RATE PER HOUR | GALLONS 4.7 |
| CQXD | HEAT DELIVERY RATE | BRITISH THERMAL UNIT 230000.0 |
| AEJZ | DEPTH | INCHES NOMINAL 69.000 |
| AKDJ | PRIME MOVER TYPE | GASOLINE ENGINE |
| ALYC | OPERATING CONTROL TYPE | THERMOSTATIC |
| ABFH | FLUE CONNECTION LOCATION | TOP MTD W/18IN. EXTENSION |
| ABGL | WIDTH | INCHES NOMINAL 42.000 |
| AAXX | MOUNTING TYPE | TRAILER |
| ABAM | HEAT MEDIUM TYPE | AIR |
| ABBA | AIR CIRCULATION DEVICE | SQUIRREL CAGE BLOWER |
| HGTH | HEIGHT | INCHES NOMINAL 48.000 |
| BDXJ | HEATING ELEMENT TYPE | COMBUSTION CHAMBER |