Home / MS parts / NSN 5925-00-876-9218
NSN 5925-00-876-9218  ·  NIIN 008769218  ·  FSC 5925
NO DASHES 5925008769218
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

37 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ADATBODY WIDTHINCHES NOMINAL 4.125
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 50.0
APNQARC QUENCHING METHODAIR
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 1.344
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 4.827
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS INSTANTANEOUS AND TIME DELAY
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 500.0
AKPXPOLE QUANTITY3
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
BBRJSPECIAL HANDLING FEATUREMAGNETIC
AAQLBODY STYLE
ADAQBODY LENGTHINCHES NOMINAL 6.500
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE TWO
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 5.000 AND MAXIMUM AT 200 PCT 15.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDSHOCK RESISTANT AND VIBRATION RESISTANT
CRCFTRIP RELEASE AMBIENT TEMP RATINGALL LOCATIONS CELSIUS NOMINAL 50.0
FEATSPECIAL FEATURESCIRCUIT BREAKER SUPPLIED WITH TWO THREADED METAL INSERTS
FREQFREQUENCY IN HERTZ60.0
MATTMATERIALCASE PLASTIC
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-17361
TTQYTERMINAL TYPE AND QUANTITYQUICK DISCONNECT, MALE 6
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--IL-C-17361 TO 4
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 7500.0
AXHRMOUNTING FACILITY TYPE AND QUANTITYUNTHREADED HOLE(S) 4
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
ADAUBODY HEIGHTINCHES NOMINAL 3.875
AEBVUNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.190
CPRJTRIP RELEASE METHODALL LOCATIONS THERMAL-MAGNETIC
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 3.688
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHTINCHES NOMINAL 0.188
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 3.938
CPRQRESET METHODMANUAL

Supersedes

This item replaces cancelled NIINs 001068164 · 000850681 · 011553944. An older drawing citing one of those numbers resolves here.