NSN 4810-00-529-3929 · NIIN 005293929 · FSC 4810
NO DASHES 4810005293929
In Stock
VALVE,LINEAR,DIRECTIONAL CONTROL
Valves, Powered
Application: ACFT HYDRAULIC SYSTEM
Technical characteristics
18 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL JOINT FINE (UNJF) |
| AMPS | CURRENT RATING IN AMPS | 1.0 |
| AQLR | VALVE OPERATION METHOD | SOLENOID |
| PRPY | PROPRIETARY CHARACTERISTICS | PACS |
| FEAT | SPECIAL FEATURES | MANUFACTURERS SUGGESTED NAME IS VALVE, THREE-WAY, TWO POSITION, SOLENOID OPERATED HYDRAULIC |
| CYHB | SPOOL QUANTITY | 1 |
| CYGY | FLOW PATTERN QUANTITY | 3 |
| CYGZ | SPOOL POSITION QUANTITY | 2 |
| CSBH | VOLTAGE IN VOLTS AND CURRENT TYPE | DC 17.0 AND DC 30.0 |
| AAJD | THREAD CLASS | 3B |
| ADQZ | END CONNECTION QUANTITY | 3 |
| CQRG | BODY MATERIAL | ALUMINUM ALLOY |
| CRWH | MAXIMUM OPERATING TEMP AND MEDIA FOR WHICH DESIGNED | FAHRENHEIT HYDRAULIC FLUID, PETROLEUM BASE 275.0 |
| ADSY | VALVE DISCHARGE FLOW RATE | GALLONS PER MINUTE 3.5 |
| AWLS | CONNECTION TYPE | THREADED INTERNAL BOSS |
| CQCJ | MAXIMUM OPERATING PRESSURE AND MEDIA FOR WHICH DESIGNED | POUNDS PER SQUARE INCH HYDRAULIC FLUID, PETROLEUM BASE 3000.0 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.563 |
| AGAV | END ITEM IDENTIFICATION | ACFT HYDRAULIC SYSTEM |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 106475-1 | 79318 |
| 4810PL1368931 | 9009H |
| 695197 | 98897 |