Home / MS parts / NSN 5925-00-928-6081
NSN 5925-00-928-6081  ·  NIIN 009286081  ·  FSC 5925
NO DASHES 5925009286081
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

40 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AKPXPOLE QUANTITY1
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRJTRIP RELEASE METHODSINGLE LOCATION MAGNETIC-HYDRAULIC
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 2
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2
CQJXNOMINAL THREAD SIZEINCHES 0.138
CQSMSWITCH LOCATION AND POSITION DESIGNATIONINTERNAL AT POLE ONE
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.400 AND MAXIMUM AT 200 PCT 1.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDFUNGUS RESISTANT AND VIBRATION RESISTANT
CRTKSWITCH TERMINAL TYPETURRET
CSSXSWITCH CURRENT RATING AND TYPE IN AMPSAC 5.0 AND DC 5.0
CSWPSWITCH VOLTAGE RATING AND TYPE IN VOLTSAC 115.0 AND DC 28.0
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
PMLCPRECIOUS MATERIAL AND LOCATIONSILVER TER-INAL SURFACES
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPRZAUXILIARY SWITCH FUNCTION AND QUANTITYALARM 1
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES DC 1.5
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
AAQLBODY STYLE
CPRQRESET METHODMANUAL
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 500.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
AEGJSWITCH CONTACT ARRANGEMENTSINGLE POLE, DOUBLE THROW
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 3.510
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 416.0
AFJNFRAGILITY FACTORMODERATELY RUGGED
AJECBOSS HEIGHTINCHES NOMINAL 0.156
PRMTPRECIOUS MATERIALSILVER
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 2.750
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 3.060
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
ADAQBODY LENGTHINCHES MAXIMUM 3.730
ADATBODY WIDTHINCHES MAXIMUM 1.000