Home / MS parts / NSN 5915-01-148-4729
NSN 5915-01-148-4729  ·  NIIN 011484729  ·  FSC 5915
NO DASHES 5915011484729
In Stock

FILTER,RADIO FREQUENCY INTERFERE

Filters and Networks

Technical characteristics

39 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABHPOVERALL LENGTHINCHES NOMINAL 2.687
ABKWOVERALL HEIGHTINCHES NOMINAL 3.469
ADAQBODY LENGTHINCHES NOMINAL 2.500
ADATBODY WIDTHINCHES NOMINAL 2.500
ADAUBODY HEIGHTINCHES NOMINAL 3.000
AECRVIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.500
AFGAOPERATING TEMP RANGECELSIUS -55.0 TO 85.0
AFSVAVERAGE LIFE RATING IN HOURS1000.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 60.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 60.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 10.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 10.0
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 2.4
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 2.4
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AHBNINPUT TERMINAL MANUFACTURER CODE33095
AHBPINPUT TERMINAL IDENTIFICATION8001-14S-7P-A3
AHCGMAXIMUM TEMP RISECELSIUS 25.0
AHCJFULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.15 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
AHCKFULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS24.0 AND 60.0 AND 80.0 AND 70.0
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 2
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION CONNECTOR, PLUG INPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION TAB, SOLDER LUG GROUND 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION TAB, SOLDER LUG OUTPUT 2
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 240.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 240.0
CQJXNOMINAL THREAD SIZEINCHES 0.164
CQRGBODY MATERIALMETAL
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEKILOVOLTS AT SEA LEVEL 1.2
FEATSPECIAL FEATURESTWO FILTERED FUNCTIONS
STYLSTYLE DESIGNATOR