NSN 6145-00-542-3404 · NIIN 005423404 · FSC 6145
NO DASHES 6145005423404
In Stock
CABLE,SPECIAL PURPOSE,ELECTRICAL
Wire and Cable, Electrical
Technical characteristics
14 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CXDG | STRAND AWG SIZE PER CONDUCTOR | 32 |
| CXDQ | CONDUCTOR ARRANGEMENT AND QUANTITY | SINGLES 12 |
| MATT | MATERIAL | CORE CONDUCTOR ALL CONDUCTORS COPPER |
| ADVL | CROSS SECTION OUTSIDE DIAMETER | INCHES NOMINAL 0.410 |
| CXCW | CONDUCTOR FORM | ALL CONDUCTORS STRANDED |
| CXDC | ROUND CONDUCTOR SIZE | ALL CONDUCTORS AWG 20 |
| MATT | MATERIAL | FIRST POSITION PRIMARY INSULATION ALL CONDUCTORS PLASTIC POLYVINYL CHLORIDE (PVC) |
| SFTT | SURFACE TREATMENT | CORE CONDUCTOR ALL CONDUCTORS TIN |
| BLNZ | STRAND QUANTITY PER CONDUCTOR | 19 |
| AAGR | CROSS-SECTIONAL SHAPE STYLE | |
| ABJH | TEMP RATING | CELSIUS -20.0 AND CELSIUS 80.0 |
| AWXS | COLOR CODING DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 5322-92194 |
| CXFK | VOLTAGE RATING | ALL CONDUCTORS MAXIMUM ROOT MEAN SQUARE (RMS) OPERATING VOLTAGE 300.0 |
| AMQN | CONDUCTOR QUANTITY | 12 |