NSN 5510-00-161-3301 · NIIN 001613301 · FSC 5510
NO DASHES 5510001613301
In Stock
POLE,LINE CONSTRUCTION,WOOD
Lumber and Related Basic Wood Materials
Technical characteristics
11 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| BMKY | TREATMENT TYPE | PRESERVATIVE, TT-W-571 |
| CKMR | FRAME ROOF TYPE | FLAT OR ONE WAY |
| CQMP | PRESERVATIVE SOLUTION TYPE | AMMONIACAL COPPER ARSENITE OR CHROMATED COPPER ARSENATE, TYPE I, II OR III OR COAL-TAR CREOSOTE OR PENTACHLOROPHENOL |
| CQWY | SPECIES-GRADE AND GRADING ASSOCIATION | CEDAR UNGRADED UNRECOGNIZED OR DOUGLAS FIR UNGRADED UNRECOGNIZED OR LARCH UNGRADED UNRECOGNIZED OR PINE UNGRADED UNRECOGNIZED |
| CRRW | GAIN TYPE AND QUANTITY | MORTISE 1 OR SLAB 1 |
| CRXX | MEASURING METHOD AND LENGTH | FEET NOMINAL SPECIFIED 40.000 |
| CSTS | TYPICAL WOOD PRODUCTS USE | COMMUNICATION AND TRANSMISSION LINES, FULL LENGTH PRESERVATIVE TREATED, GAINED AND BORED FOR TWO STANDARD CROSSARMS |
| CSTZ | SERVICE USAGE | UTILITY |
| FEAT | SPECIAL FEATURES | FOR 2 STD 4.500 IN. CROSS ARMS,2 HOLES DRILLED 0.688 IN. DIA,SPACED 24.000 IN. APART W/CENTER OF TOP HOLE 10.250 IN. PORM 0.250 IN. FROM PEAK OF ROOF,POLES SHALL BE CLEAN PEELED,THE AMERICAN NATIONAL STANDARDS INSTITUTE CLASS 4 |
| SUPP | SUPPLEMENTARY FEATURES | TYPICAL USE--FOR COMMUNICATION AND TRANSMISSION LINES,UNIT OF ISSUE--EACH |
| ZZZT | NONDEFINITIVE SPEC/STD DATA | CLASS 4 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| MM-P-371 | 81348 |