NSN 5905-00-594-2644 · NIIN 005942644 · FSC 5905
NO DASHES 5905005942644
In Stock
RESISTOR,VARIABLE,NONWIRE WOUND,
Resistor
Technical characteristics
25 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABXF | SHAFT LENGTH | INCHES MAXIMUM 0.080 |
| TTQY | TERMINAL TYPE AND QUANTITY | PIN 3 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-39035 |
| AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.100 |
| ABJT | TERMINAL LENGTH | INCHES MINIMUM 0.300 |
| ADAT | BODY WIDTH | INCHES NOMINAL 0.170 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 0.375 |
| ABWV | SHAFT DIAMETER | INCHES NOMINAL 0.075 |
| AAPN | SECTION QUANTITY | 1 |
| AAQL | BODY STYLE | |
| CRFJ | TEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS | SINGLE SECTION -100.0 TO 100.0 |
| CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | FREE AIR SINGLE SECTION 0.5 |
| CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | SINGLE SECTION -10.0 TO 10.0 |
| CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | SINGLE SECTION 85.0 |
| AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | INCHES NOMINAL 0.200 |
| AEDX | SHAFT STYLE | |
| AEFD | ACTUATOR TYPE | SINGLE SHAFT |
| CQTM | TERMINAL LOCATION | REAR END |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-R-39035 TO 2 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 0.420 |
| AXGY | MOUNTING METHOD | TERMINAL |
| AARG | RELIABILITY INDICATOR | ESTABLISHED |
| CQCC | ELECTRICAL RESISTANCE PER SECTION | KILOHMS SINGLE SECTION 25.0 |
| CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | INCHES NOMINAL 0.100 |
| CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | SINGLE SECTION 150.0 |
Cross-references
5 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| RJR24FW253M | 81349 |
| MIL-PRF-39035/2 | 81349 |
| RJR24FW253P | 81349 |
| MILR39035-2 | 81349 |
| M175PCT253A | 11068 |