RESISTOR,THERMAL
Resistor
Technical characteristics
51 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CGGK | MOUNTING THREAD QUANTITY | PER INCH 32 |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.1 TO 15.1 |
| STYL | STYLE DESIGNATOR | |
| CQWD | ZERO POWER RESISTANCE | OHMS 200.000 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | NINTH RESISTANCE-TEMPERATURE POINT OHMS 8.0 |
| CRQJ | ZERO POWER RESISTANCE TOLERANCE IN PERCENT AT REFERENCE TEMP | -10.0 TO 10.0 |
| CRYY | MOUNTING FACILITY NOMINAL SCREW THREAD DIAMETER | INCHES 0.250 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | SIXTH RESISTANCE-TEMPERATURE POINT OHMS 48.0 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | SECOND RESISTANCE-TEMPERATURE POINT KILOHMS 2.2 |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -13.4 TO 13.4 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | FOURTH RESISTANCE-TEMPERATURE POINT OHMS 280.0 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
| AASA | THREAD LENGTH | INCHES NOMINAL 0.375 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | SEVENTH RESISTANCE-TEMPERATURE POINT OHMS 26.0 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 0.500 |
| AEBT | TERMINAL DIAMETER | INCHES NOMINAL 0.032 |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | CELSIUS 25.0 |
| AEHZ | MAXIMUM OPERATING TEMP | CELSIUS 150.0 |
| AEJA | THERMAL TIME CONSTANT IN SECONDS | 11.0 |
| AEJB | POWER DISSIPATION CONSTANT IN MILLIWATTS PER DEG CELSIUS | 25.0 |
| AEJC | ZERO POWER TEMP COEFFICIENT OF RESISTANCE IN PERCENT PER DEG CELSIUS | M3.96 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | EIGHTH RESISTANCE-TEMPERATURE POINT CELSIUS 100.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIFTH RESISTANCE-TEMPERATURE POINT CELSIUS 40.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FIRST RESISTANCE-TEMPERATURE POINT CELSIUS -40.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | FOURTH RESISTANCE-TEMPERATURE POINT CELSIUS 20.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | NINTH RESISTANCE-TEMPERATURE POINT CELSIUS 120.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SECOND RESISTANCE-TEMPERATURE POINT CELSIUS -20.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SEVENTH RESISTANCE-TEMPERATURE POINT CELSIUS 80.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | SIXTH RESISTANCE-TEMPERATURE POINT CELSIUS 60.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | TENTH RESISTANCE-TEMPERATURE POINT CELSIUS 140.0 |
| AEJD | TEMP POINTS FOR RESISTANCE READINGS AT ZERO POWER | THIRD RESISTANCE-TEMPERATURE POINT CELSIUS 0.0 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | EIGHTH RESISTANCE-TEMPERATURE POINT OHMS 13.2 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIFTH RESISTANCE-TEMPERATURE POINT OHMS 100.0 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | FIRST RESISTANCE-TEMPERATURE POINT KILOHMS 8.4 |
| SFTT | SURFACE TREATMENT | TERMINAL SOLDER |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -21.9 TO 21.9 |
| TTQY | TERMINAL TYPE AND QUANTITY | WIRE LEAD 2 |
| ABJT | TERMINAL LENGTH | INCHES NOMINAL 6.000 |
| ASDB | WIDTH ACROSS FLATS | INCHES NOMINAL 0.375 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | TENTH RESISTANCE-TEMPERATURE POINT OHMS 5.0 |
| AEJE | ZERO POWER RESISTANCE AT SPECIFIED TEMP | THIRD RESISTANCE-TEMPERATURE POINT OHMS 726.0 |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -11.2 TO 11.2 |
| CBME | CUBIC MEASURE | CUBIC INCHES 0.101 |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -15.5 TO 15.5 |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -17.1 TO 17.1 |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.4 TO 18.4 |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -18.9 TO 18.9 |
| AEJF | RESISTANCE TOLERANCE AT A SPECIFIED TEMP IN PERCENT | -20.2 TO 20.2 |
| CTGT | REFERENCE TEMP IN DEG CELSIUS | 25.0 |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNEF |