NSN 5905-00-976-3501 · NIIN 009763501 · FSC 5905
NO DASHES 5905009763501
In Stock
RESISTOR,FIXED,WIRE WOUND
Resistor
Technical characteristics
17 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AEFB | POWER DISSIPATION RATING IN WATTS | FREE AIR 0.150 |
| STYL | STYLE DESIGNATOR | |
| AAPP | ELECTRICAL RESISTANCE | KILOHMS 1.210 |
| CSCF | TERMINAL TYPE | WIRE LEAD |
| AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0 TO 145.0 |
| ABPM | BODY DIAMETER | INCHES NOMINAL 0.250 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 0.500 |
| ZZZK | SPECIFICATION/STANDARD DATA | GOVERNMENT SPECIFICATION 81349--IL-R-39005 TO 4 |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010 |
| ABJT | TERMINAL LENGTH | INCHES MINIMUM 1.500 |
| AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0 TO 10.0 |
| AEHY | AMBIENT TEMP AT FULL RATED POWER | CELSIUS 125.0 |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -1.000 TO 1.000 |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0 |
| TEST | TEST DATA DOCUMENT | SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-R-39005 |
| AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
Cross-references
5 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| MILR93-13 | 81349 |
| MIL-PRF-39005/4 | 81349 |
| RB55CE12100F | 81349 |
| RBR55L12100FR | 81349 |
| MIL-R-39005/4 | 81349 |
Supersedes
This item replaces cancelled NIINs 001090323 · 007104407 · 007245753 · 009417568. An older drawing citing one of those numbers resolves here.