Home / MS parts / NSN 5915-00-005-2619
NSN 5915-00-005-2619  ·  NIIN 000052619  ·  FSC 5915
NO DASHES 5915000052619
In Stock

FILTER,BAND PASS

Filters and Networks

Technical characteristics

28 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AFGAOPERATING TEMP RANGECELSIUS -20.0 TO 71.0
AHAJREFERENCE FREQUENCY PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 484.775
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 50.0
AHASLOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST BAND PASS 50.0
AHASLOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND BAND PASS 50.0
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION CRYSTAL 1ST BAND PASS
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION CRYSTAL 2ND BAND PASS
AHAJREFERENCE FREQUENCY PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 484.475
AECRVIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 2000.0
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSSECOND FUNCTION MINIMUM 2ND BAND PASS 30.0 AND MAXIMUM 2ND BAND PASS 1.5
STYLSTYLE DESIGNATOR
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION PIN INPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION PIN OUTPUT 4
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN GROUND 2
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 483.675 AND KILOHERTZ 1ST BAND PASS 484.45 AND KILOHERTZ 1ST BAND PASS 484.50 AND KILOHERTZ 1ST BAND PASS 485.275
CQFCSPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 483.975 AND KILOHERTZ 2ND BAND PASS 484.75 AND KILOHERTZ 2ND BAND PASS 484.80 AND KILOHERTZ 2ND BAND PASS 485.575
CRBBFREQUENCY BAND WIDTH PER FUNCTIONFIRST FUNCTION KILOHERTZ 1ST BAND PASS 484.45 AND KILOHERTZ 1ST BAND PASS 484.50
CRBBFREQUENCY BAND WIDTH PER FUNCTIONSECOND FUNCTION KILOHERTZ 2ND BAND PASS 484.75 AND KILOHERTZ 2ND BAND PASS 484.80
CRBCDISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELSFIRST FUNCTION MINIMUM 1ST BAND PASS 30.0 AND MAXIMUM 1ST BAND PASS 1.5
ADAQBODY LENGTHINCHES MAXIMUM 1.510
ADATBODY WIDTHINCHES MAXIMUM 1.120
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED TERMINAL 7
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSFIRST FUNCTION 1ST BAND PASS 3.0
CQDRINSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELSSECOND FUNCTION 2ND BAND PASS 3.0
ABHPOVERALL LENGTHINCHES MAXIMUM 1.510
ABKWOVERALL HEIGHTINCHES MAXIMUM 0.595

Cross-references

5 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
B483AJ3155267
BFN04-3171034
930020-3182577
F13212-3182567
6580A3117304