NSN 5915-00-006-1202 · NIIN 000061202 · FSC 5915
NO DASHES 5915000061202
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
36 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 220.0 AND VOLTS DC 1ST RADIO INTERFERENCE 600.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 220.0 AND VOLTS DC 2ND RADIO INTERFERENCE 600.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 220.0 AND VOLTS DC 3RD RADIO INTERFERENCE 600.0 |
| CQRG | BODY MATERIAL | METAL |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | KILOVOLTS AT SEA LEVEL 1.2 |
| STYL | STYLE DESIGNATOR | |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 2.750 |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 2000.0 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 0.375 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -55.0 TO 85.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 6.5 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | THIRD FUNCTION 3RD RADIO INTERFERENCE 6.5 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AHBX | DISTANCE BETWEEN MOUNTING SURFACE AND LOWER END | INCHES NOMINAL 1.060 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION TAB, SOLDER LUG INPUT 3 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION TAB, SOLDER LUG OUTPUT 3 |
| ABHP | OVERALL LENGTH | INCHES NOMINAL 3.250 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.880 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.250 |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.875 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.880 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.205 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | THIRD FUNCTION 3RD RADIO INTERFERENCE 400.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 6.5 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 400.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 400.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |