NSN 5915-00-136-6360 · NIIN 001366360 · FSC 5915
NO DASHES 5915001366360
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
15 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ABHP | OVERALL LENGTH | INCHES NOMINAL 8.250 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 7.500 |
| ADAT | BODY WIDTH | INCHES NOMINAL 4.000 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 3.000 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.210 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 6.750 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 3.250 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 10.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 10.0 |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 125.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS DC 2ND RADIO INTERFERENCE 100.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION THREADED STUD OUTPUT 2 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION THREADED STUD INPUT 2 |
Cross-references
1 manufacturer part number on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| A1015 | 23939 |