NSN 5915-00-194-9570 · NIIN 001949570 · FSC 5915
NO DASHES 5915001949570
In Stock
FILTER,LOW PASS
Filters and Networks
Technical characteristics
22 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | LOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 50.0 |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.562 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | THIRD FUNCTION TAB, SOLDER LUG GROUND 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION TAB, SOLDER LUG INPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION TAB, SOLDER LUG OUTPUT 1 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.500 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 2.188 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 4 |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 3.0 |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.562 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 1.00 AND HERTZ BLANK 420.00 AND HERTZ BLANK 800.00 AND KILOHERTZ BLANK 1.60 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.138 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 1.188 |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 210.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | LOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 50.0 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.062 |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED HERTZ BLANK 1.00 AND HERTZ BLANK 420.00 |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| STYL | STYLE DESIGNATOR | |
| CQRG | BODY MATERIAL | METAL |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MAXIMUM BLANK 3.0 AND MINIMUM BLANK 45.0 |