NSN 5915-00-215-0183 · NIIN 002150183 · FSC 5915
NO DASHES 5915002150183
In Stock
FILTER,RADIO FREQUENCY INTERFERE
Filters and Networks
Technical characteristics
65 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| STYL | STYLE DESIGNATOR | |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | THIRD FUNCTION 3RD RADIO INTERFERENCE 1.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIFTH FUNCTION MILLIVOLTS DC 5TH RADIO INTERFERENCE 500.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 2.5 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 2.5 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 2.5 |
| ABKW | OVERALL HEIGHT | INCHES NOMINAL 3.000 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 2.750 |
| ADAT | BODY WIDTH | INCHES NOMINAL 2.000 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.500 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 2.500 |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 2000.0 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 1.500 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -54.0 TO 85.0 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | THIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
| AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 4 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION TAB, SOLDER LUG INPUT 6 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION TAB, SOLDER LUG OUTPUT 6 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | THIRD FUNCTION TAB, SOLDER LUG GROUND 2 |
| CQDZ | MAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE | VOLTS AT SEA LEVEL 350.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIFTH FUNCTION VOLTS DC 5TH RADIO INTERFERENCE 28.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | FOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 115.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | SIXTH FUNCTION VOLTS DC 6TH RADIO INTERFERENCE 28.0 |
| CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 115.0 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.112 |
| CQRG | BODY MATERIAL | METAL |
| CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | VOLTS AT SEA LEVEL 100.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | SIXTH FUNCTION MILLIVOLTS DC 6TH RADIO INTERFERENCE 500.0 |
| AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | THIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 2.5 |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIFTH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | FOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
| AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | SECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | FIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | FIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | FOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | SECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | SIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | THIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FIRST FUNCTION 1ST RADIO INTERFERENCE 400.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | FOURTH FUNCTION 4TH RADIO INTERFERENCE 400.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | SECOND FUNCTION 2ND RADIO INTERFERENCE 400.0 |
| AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | THIRD FUNCTION 3RD RADIO INTERFERENCE 400.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIFTH FUNCTION 5TH RADIO INTERFERENCE 1.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FIRST FUNCTION 1ST RADIO INTERFERENCE 1.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | FOURTH FUNCTION 4TH RADIO INTERFERENCE 1.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SECOND FUNCTION 2ND RADIO INTERFERENCE 1.0 |
| AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | SIXTH FUNCTION 6TH RADIO INTERFERENCE 1.0 |