FILTER,RADIO FREQUENCY INTERFERE

Filters and Networks

Technical characteristics

45 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 60.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 60.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHBNINPUT TERMINAL MANUFACTURER CODE96906
AHBPINPUT TERMINAL IDENTIFICATIONMS3102R36-5P
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AFSVAVERAGE LIFE RATING IN HOURS250.0
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AHAUINPUT IMPEDANCE PER FUNCTION W/LOADFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 40.0
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION MILLIVOLTS AC 1ST RADIO INTERFERENCE 100.0
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION MILLIVOLTS AC 2ND RADIO INTERFERENCE 100.0
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONTHIRD FUNCTION MILLIVOLTS AC 3RD RADIO INTERFERENCE 100.0
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
ADATBODY WIDTHINCHES NOMINAL 11.500
ADAUBODY HEIGHTINCHES NOMINAL 2.750
AHASLOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 40.0
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION THREADED STUD INPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION THREADED STUD OUTPUT 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION SOLDER STUD GROUND 2
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 440.0
ABHPOVERALL LENGTHINCHES NOMINAL 12.937
ABKWOVERALL HEIGHTINCHES NOMINAL 3.550
ADAQBODY LENGTHINCHES NOMINAL 12.062
AHAUINPUT IMPEDANCE PER FUNCTION W/LOADSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHAUINPUT IMPEDANCE PER FUNCTION W/LOADTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHAVOUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHAVOUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHAVOUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUTTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 60.0
AEBVUNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.250
AFGAOPERATING TEMP RANGECELSIUS -65.0 TO 85.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 40.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 440.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 440.0
CQRGBODY MATERIALMETAL
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEKILOVOLTS AT SEA LEVEL 1.9
STYLSTYLE DESIGNATOR

Cross-references

4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
A254259901
66168-182340
RF389913619
RF0389913619