NSN 5915-00-410-5396 · NIIN 004105396 · FSC 5915
NO DASHES 5915004105396
In Stock
FILTER,BAND PASS
Filters and Networks
Technical characteristics
25 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | THIRD FUNCTION PIN GROUND 1 |
| STYL | STYLE DESIGNATOR | |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM BLANK 90.0 AND MAXIMUM BLANK 3.0 |
| ABKW | OVERALL HEIGHT | INCHES MAXIMUM 0.890 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 5.00 AND KILOHERTZ BLANK 7.395 AND KILOHERTZ BLANK 7.605 AND KILOHERTZ BLANK 10.00 |
| CQRG | BODY MATERIAL | PLASTIC |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 0.500 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -30.0 TO 85.0 |
| AFSV | AVERAGE LIFE RATING IN HOURS | 1000.0 |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 7.5 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED TERMINAL 5 |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 3.0 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION PIN INPUT 2 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION PIN OUTPUT 2 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | LOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 10.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 1.0 |
| AKNA | INCLOSURE TYPE | ENCAPSULATED |
| AECR | VIBRATION RESISTANCE RANGE IN HERTZ | 10.0 TO 500.0 |
| AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 5.0 |
| ADAQ | BODY LENGTH | INCHES NOMINAL 1.400 |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.200 |
| ADAU | BODY HEIGHT | INCHES MAXIMUM 0.680 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 1.200 |
| AHAS | LOAD IMPEDANCE PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED KILOHMS BLANK 5.0 |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED KILOHERTZ BLANK 7.395 AND KILOHERTZ BLANK 7.605 |