NSN 5915-00-737-0924 · NIIN 007370924 · FSC 5915
NO DASHES 5915007370924
In Stock
FILTER,BAND PASS
Filters and Networks
Technical characteristics
26 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.453 |
| AHCH | AVERAGE POWER RATING PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED WATTS BLANK 150.0 |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES NOMINAL 3.938 |
| ABHP | OVERALL LENGTH | INCHES MAXIMUM 4.812 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.188 |
| AKNA | INCLOSURE TYPE | ENCASED |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | LOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4 |
| CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | LOCATION NOT OTHERWISE SPECIFIED BLANK 0.4 |
| AHAJ | REFERENCE FREQUENCY PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 478.0 |
| AHAU | INPUT IMPEDANCE PER FUNCTION W/LOAD | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHAV | OUTPUT IMPEDANCE PER FUNCTION W/SOURCE ACROSS INPUT | LOCATION NOT OTHERWISE SPECIFIED OHMS BLANK 50.0 |
| AHBZ | VOLTAGE STANDING WAVE RATIO PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED BLANK 1.5 |
| CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | FIRST FUNCTION MINIMUM BLANK 50.0 AND MAXIMUM BLANK 3.0 |
| ADAT | BODY WIDTH | INCHES NOMINAL 1.531 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | FIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1 |
| CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | SECOND FUNCTION CONNECTOR, RECEPTACLE OUTPUT 1 |
| CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 275.00 AND MEGAHERTZ BLANK 406.00 AND MEGAHERTZ BLANK 550.00 AND MEGAHERTZ BLANK 680.00 |
| CQRG | BODY MATERIAL | METAL |
| CRBB | FREQUENCY BAND WIDTH PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 406.00 AND MEGAHERTZ BLANK 550.00 |
| CRBN | VOLTAGE STANDING WAVE RATIO FREQUENCY LIMITS PER FUNCTION | LOCATION NOT OTHERWISE SPECIFIED MEGAHERTZ BLANK 406.0 AND MEGAHERTZ BLANK 550.0 |
| FEAT | SPECIAL FEATURES | UNPACKAGED UNIT WEIGHT: LB2.000 |
| STYL | STYLE DESIGNATOR | |
| TEST | TEST DATA DOCUMENT | DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING) 10001-2451026 |
| AFGA | OPERATING TEMP RANGE | CELSIUS -28.0 TO 65.0 |
| AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | INCHES NOMINAL 1.000 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.125 |