FILTER,RADIO FREQUENCY INTERFERE

Filters and Networks

Technical characteristics

47 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABHPOVERALL LENGTHINCHES NOMINAL 10.500
ABKWOVERALL HEIGHTINCHES NOMINAL 4.000
ADAQBODY LENGTHINCHES NOMINAL 8.500
ADATBODY WIDTHINCHES NOMINAL 3.000
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 9.500
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 2.000
AFGAOPERATING TEMP RANGECELSIUS -55.0 TO 85.0
AFSVAVERAGE LIFE RATING IN HOURS10000.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 440.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFOURTH FUNCTION 4TH RADIO INTERFERENCE 440.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 440.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 440.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 11.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 11.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 11.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 11.0
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONFOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 2.4
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 2.4
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 2.4
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 2.4
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED THREADED HOLE(S) 4
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION WIRE LEAD INPUT 4
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION THREADED STUD GROUND 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION WIRE LEAD OUTPUT 4
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 130.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 130.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 130.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 130.0
CQJXNOMINAL THREAD SIZEINCHES 0.190
CQRGBODY MATERIALMETAL
CRSTBODY SURFACE TREATMENTTIN
FEATSPECIAL FEATURESWIRE LEAD TERMINALS 48.000 IN. LG MIN
STYLSTYLE DESIGNATOR

Cross-references

10 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
2131970-719315
82-346-00133095
2131970-755974
A390159901
CSK-370772982
5004-453313050
CSK-370712294
F20596-713675
RF04858-713619
RF4858-713619