Home / MS parts / NSN 5915-01-341-6886
NSN 5915-01-341-6886  ·  NIIN 013416886  ·  FSC 5915
NO DASHES 5915013416886
In Stock

FILTER,RADIO FREQUENCY INTERFERE

Filters and Networks

Application: G202433

Technical characteristics

52 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABHPOVERALL LENGTHINCHES NOMINAL 17.250
ABKWOVERALL HEIGHTINCHES NOMINAL 8.406
ADAQBODY LENGTHINCHES NOMINAL 16.000
ADATBODY WIDTHINCHES NOMINAL 5.000
ADAUBODY HEIGHTINCHES MAXIMUM 6.000
AEBVUNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.199
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 16.625
AECRVIBRATION RESISTANCE RANGE IN HERTZ5.0 TO 55.0
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 5.626
AFGAOPERATING TEMP RANGECELSIUS 0.0 TO 85.0
AFSVAVERAGE LIFE RATING IN HOURS10000.0
AGAVEND ITEM IDENTIFICATIONG202433
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 60.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 60.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 60.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 25.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 25.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 25.0
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 1.2
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 1.2
AHBEMAXIMUM VOLTAGE DROP PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 1.2
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AHBNINPUT TERMINAL MANUFACTURER CODE96906
AHBPINPUT TERMINAL IDENTIFICATIONMS3402DS22-22P
AHCGMAXIMUM TEMP RISECELSIUS 40.0
AHCHAVERAGE POWER RATING PER FUNCTIONFIRST FUNCTION WATTS 1ST RADIO INTERFERENCE 60.0
AHCHAVERAGE POWER RATING PER FUNCTIONSECOND FUNCTION WATTS 2ND RADIO INTERFERENCE 60.0
AHCHAVERAGE POWER RATING PER FUNCTIONTHIRD FUNCTION WATTS 3RD RADIO INTERFERENCE 60.0
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 14
CBBLFEATURES PROVIDEDSHOCK RESISTANT
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYTHIRD FUNCTION PIN GROUND 1
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYSECOND FUNCTION THREADED STUD OUTPUT 3
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYFIRST FUNCTION CONNECTOR, RECEPTACLE INPUT 1
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 440.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 440.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 440.0
CQRGBODY MATERIALMETAL
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGEKILOVOLTS AT SEA LEVEL 2.5
CRSTBODY SURFACE TREATMENTTIN
FEATSPECIAL FEATURESTHREE FILTERED FUNCTIONS
PMLCPRECIOUS MATERIAL AND LOCATIONGOLD CONTACT SURFACES
PRMTPRECIOUS MATERIALGOLD
STYLSTYLE DESIGNATOR

Cross-references

3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
G281269-13B150
G281269-149956
G281269-154X10