Home / MS parts / NSN 5915-01-357-3303
NSN 5915-01-357-3303  ·  NIIN 013573303  ·  FSC 5915
NO DASHES 5915013573303
In Stock

FILTER,RADIO FREQUENCY INTERFERE

Filters and Networks

Application: 1520-01-298-4532 BRACE,BOMB RACK

Technical characteristics

53 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
ABHPOVERALL LENGTHINCHES NOMINAL 2.140
ABKWOVERALL HEIGHTINCHES NOMINAL 1.562
ABMKOVERALL WIDTHINCHES NOMINAL 1.250
AEBVUNTHREADED MOUNTING HOLE DIAMETERINCHES NOMINAL 0.120
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 1.250
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 1.250
AFGAOPERATING TEMP RANGECELSIUS -55.0 TO 125.0
AGAVEND ITEM IDENTIFICATION1520-01-298-4532 BRACE,BOMB RACK
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONFIFTH FUNCTION OHMS 5TH RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONSIXTH FUNCTION OHMS 6TH RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONFIRST FUNCTION OHMS 1ST RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONSECOND FUNCTION OHMS 2ND RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONTHIRD FUNCTION OHMS 3RD RADIO INTERFERENCE 50.0
AHASLOAD IMPEDANCE PER FUNCTIONFOURTH FUNCTION OHMS 4TH RADIO INTERFERENCE 50.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIFTH FUNCTION 5TH RADIO INTERFERENCE 425.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFIRST FUNCTION 1ST RADIO INTERFERENCE 425.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZFOURTH FUNCTION 4TH RADIO INTERFERENCE 425.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSIXTH FUNCTION 6TH RADIO INTERFERENCE 425.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZTHIRD FUNCTION 3RD RADIO INTERFERENCE 425.0
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZSECOND FUNCTION 2ND RADIO INTERFERENCE 425.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSFOURTH FUNCTION 4TH RADIO INTERFERENCE 32.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSSIXTH FUNCTION 6TH RADIO INTERFERENCE 1.5
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSFIFTH FUNCTION 5TH RADIO INTERFERENCE 1.5
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSTHIRD FUNCTION 3RD RADIO INTERFERENCE 32.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSFIRST FUNCTION 1ST RADIO INTERFERENCE 32.0
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPSSECOND FUNCTION 2ND RADIO INTERFERENCE 32.0
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIFTH FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONFOURTH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONSIXTH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONSECOND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONTHIRD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONFIRST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE
AKNAINCLOSURE TYPEHERMETICALLY SEALED
AXHRMOUNTING FACILITY TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED UNTHREADED HOLE(S) 4
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITYLOCATION NOT OTHERWISE SPECIFIED FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT 12
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSIXTH FUNCTION VOLTS AC 6TH RADIO INTERFERENCE 180.0 AND VOLTS DC 6TH RADIO INTERFERENCE 500.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFOURTH FUNCTION VOLTS AC 4TH RADIO INTERFERENCE 180.0 AND VOLTS DC 4TH RADIO INTERFERENCE 500.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIFTH FUNCTION VOLTS AC 5TH RADIO INTERFERENCE 180.0 AND VOLTS DC 5TH RADIO INTERFERENCE 500.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONSECOND FUNCTION VOLTS AC 2ND RADIO INTERFERENCE 180.0 AND VOLTS DC 2ND RADIO INTERFERENCE 500.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONFIRST FUNCTION VOLTS AC 1ST RADIO INTERFERENCE 180.0 AND VOLTS DC 1ST RADIO INTERFERENCE 500.0
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTIONTHIRD FUNCTION VOLTS AC 3RD RADIO INTERFERENCE 180.0 AND VOLTS DC 3RD RADIO INTERFERENCE 500.0
CQRGBODY MATERIALMETAL
CTJSUNPACKAGED UNIT WEIGHTOUNCES NOMINAL 6.500
FEATSPECIAL FEATURESTWELVE FILTERED FUNCTIONS
PMLCPRECIOUS MATERIAL AND LOCATIONSILVER CONTACT SURFACES
PRMTPRECIOUS MATERIALSILVER
STYLSTYLE DESIGNATOR

Cross-references

7 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
1255-080-000733095
90291-173030
21-900419-00377820
21-900419-00177820
90291-107148
1255-080-00070LSP2
1255-080-000712294