NSN 5925-00-059-1140 · NIIN 000591140 · FSC 5925
NO DASHES 5925000591140
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
29 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 800.0 AND DC 2000.0 |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.469 |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 2.000 AND MAXIMUM AT 200 PCT 20.000 |
| AKPX | POLE QUANTITY | 1 |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED BUSHING 1 |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 7.5 AND AMPERES DC 7.5 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 115.0 AND DC 28.0 |
| AAQL | BODY STYLE | |
| ABXD | BUSHING LENGTH | INCHES MINIMUM 0.273 AND INCHES MAXIMUM 0.293 |
| ADAQ | BODY LENGTH | INCHES MAXIMUM 0.780 |
| ADAT | BODY WIDTH | INCHES MAXIMUM 0.593 |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 145.0 |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | PUSH-PULL 1 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 0.672 AND INCHES MAXIMUM 0.734 |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MAXIMUM 1.812 |
| THSD | THREAD SERIES DESIGNATOR | UNS |
| TTQY | TERMINAL TYPE AND QUANTITY | SCREW 2 |
| FREQ | FREQUENCY IN HERTZ | 400.0 |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | SINGLE LOCATION CELSIUS NOMINAL 25.0 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | CORROSION RESISTANT AND DUSTPROOF AND EXPLOSION PROOF AND MOISTURE RESISTANT AND SAND RESISTANT AND FUNGUS RESISTANT |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION THERMAL |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
Cross-references
12 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 10502001 | 56161 |
| 4001-001-7 1/2 | 76374 |
| AS22073 | 81343 |
| AS58091 | 81343 |
| MS22073-7-1/2 | 81343 |
| MIL-C-5809 | 81349 |
| MS22073-7-1-2A | 96906 |
| MS22073-75 | 96906 |
| MS22073-7-1-2 | 96906 |
| AS58091 | 0U583 |
| MS22073-7-1/2 | 0U583 |
| SAE-AS58091 | 0U583 |
Supersedes
This item replaces cancelled NIIN 010445627. An older drawing citing one of those numbers resolves here.