Home / MS parts / NSN 5925-00-185-4014
NSN 5925-00-185-4014  ·  NIIN 001854014  ·  FSC 5925
NO DASHES 5925001854014
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

36 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRQRESET METHODMANUAL
CMLPTHREAD QUANTITY PER INCH32
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLESINGLE LOCATION AMPERES AC 5.0
TTQYTERMINAL TYPE AND QUANTITYTHREADED STUD 2
ZZZKSPECIFICATION/STANDARD DATAGOVERNMENT SPECIFICATION 81349--55625 TO 1
BBRJSPECIAL HANDLING FEATUREMAGNETIC
TESTTEST DATA DOCUMENTSPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). 81349--IL-C-55629
CPRTMANUAL ACTUATOR TYPE AND QUANTITYTOGGLE 1
AAQLBODY STYLE
ADAQBODY LENGTHINCHES MAXIMUM 2.510
ADATBODY WIDTHINCHES MINIMUM 0.730 AND INCHES MAXIMUM 0.780
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES MINIMUM 1.660 AND INCHES MAXIMUM 1.960
CQJXNOMINAL THREAD SIZEINCHES 0.138
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)
AKPXPOLE QUANTITY1
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES MINIMUM 2.046 AND INCHES MAXIMUM 2.078
AFJNFRAGILITY FACTORMODERATELY RUGGED
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSSINGLE LOCATION AC 240.0
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSSINGLE LOCATION AC 1000.0
CPRHCIRCUIT PROTECTION TYPESINGLE LOCATION OVERCURRENT
CPRJTRIP RELEASE METHODSINGLE LOCATION MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICSINGLE LOCATION TIME DELAY
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT150.0
CPRWACTUATOR FUNCTIONTRIP-RESET
CPRXACTUATOR POSITION DESIGNATIONAT POLE ONE
CPSMINTERNAL TRIP RELEASE CONFIGURATIONSINGLE LOCATION SERIES TRIP
APNQARC QUENCHING METHODMAGNETIC BLOWOUT
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTSINGLE LOCATION MINIMUM AT 200 PCT 0.050 AND MAXIMUM AT 200 PCT 10.000
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDMOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT
FREQFREQUENCY IN HERTZ60.0
MATTMATERIALCASE PLASTIC
AJECBOSS HEIGHTINCHES NOMINAL 0.140
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES MAXIMUM 2.553
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 2

Cross-references

9 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
5SE01329-1028638
76-12D5-538597
AM1-A3-5-250AC-374193
MIL-C-55629/181349
M55629/1-04681349
M55629/1-046L81349
MIL-PRF-55629/181349
APL1-1-61-502-M81541
APL1-55629-1-04681541

Supersedes

This item replaces cancelled NIINs 000892903 · 007764325. An older drawing citing one of those numbers resolves here.