NSN 5925-00-400-1561 · NIIN 004001561 · FSC 5925
NO DASHES 5925004001561
In Stock
CIRCUIT BREAKER
Circuit Breakers
Application: LOGISTICS SUPPORT VESSEL
Technical characteristics
30 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| FREQ | FREQUENCY IN HERTZ | 60.0 |
| CPRJ | TRIP RELEASE METHOD | ALL LOCATIONS THERMAL-MAGNETIC |
| CPRL | TRIP RELEASE CHARACTERISTIC | ALL LOCATIONS TIME DELAY |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | ALL LOCATIONS NOMINAL AT 150 PCT 60.000 AND NOMINAL AT 200 PCT 20.000 AND NOMINAL AT 300 PCT 6.000 |
| ADAU | BODY HEIGHT | INCHES NOMINAL 2.375 |
| TTQY | TERMINAL TYPE AND QUANTITY | CLIP 2 AND COMPRESSION 2 |
| CPRH | CIRCUIT PROTECTION TYPE | ALL LOCATIONS OVERCURRENT |
| CRCF | TRIP RELEASE AMBIENT TEMP RATING | ALL LOCATIONS CELSIUS NOMINAL 40.0 |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| AGAV | END ITEM IDENTIFICATION | LOGISTICS SUPPORT VESSEL |
| AJEC | BOSS HEIGHT | INCHES NOMINAL 0.187 |
| AKPX | POLE QUANTITY | 2 |
| APNQ | ARC QUENCHING METHOD | AIR |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | TERMINAL 4 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | ALL LOCATIONS AMPERES AC 30.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | ALL LOCATIONS AC 240.0 |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | INCHES NOMINAL 1.000 |
| CPRQ | RESET METHOD | MANUAL |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 2 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| MATT | MATERIAL | CASE PLASTIC |
| CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE AND TWO LINKED |
| ADAT | BODY WIDTH | INCHES NOMINAL 2.000 |
| AAQL | BODY STYLE | |
| ADAQ | BODY LENGTH | INCHES NOMINAL 3.125 |
| CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | ALL LOCATIONS AC 10000.0 |
Cross-references
9 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
Supersedes
This item replaces cancelled NIINs 008325296 · 010302958 · 012710693. An older drawing citing one of those numbers resolves here.