NSN 5925-00-491-2363 · NIIN 004912363 · FSC 5925
NO DASHES 5925004912363
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
32 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION DC 50.0 |
| CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | THREADED HOLE(S) 2 |
| AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | INCHES MINIMUM 1.555 AND INCHES MAXIMUM 1.565 |
| CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
| AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | INCHES MINIMUM 1.875 AND INCHES MAXIMUM 1.885 |
| AAQL | BODY STYLE | |
| ADAQ | BODY LENGTH | INCHES MINIMUM 1.985 AND INCHES MAXIMUM 2.015 |
| ADAT | BODY WIDTH | INCHES MINIMUM 0.745 AND INCHES MAXIMUM 0.755 |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION MAGNETIC-HYDRAULIC |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| AKPX | POLE QUANTITY | 1 |
| APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION MILLIAMPERES DC 400.0 |
| CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | TOGGLE 1 |
| CPRW | ACTUATOR FUNCTION | TRIP-RESET |
| AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | INCHES MINIMUM 1.655 AND INCHES MAXIMUM 1.665 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| CMLP | THREAD QUANTITY PER INCH | 32 |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 |
| CPRQ | RESET METHOD | MANUAL |
| THSD | THREAD SERIES DESIGNATOR | UNIFIED NATIONAL COARSE (UNC) |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SINGLE LOCATION SERIES TRIP |
| CQJX | NOMINAL THREAD SIZE | INCHES 0.138 |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 0.900 AND MAXIMUM AT 200 PCT 12.000 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | DUSTPROOF |
| MATT | MATERIAL | CASE PLASTIC |
| TTQY | TERMINAL TYPE AND QUANTITY | THREADED STUD 2 |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| AJEC | BOSS HEIGHT | INCHES MINIMUM 0.125 AND INCHES MAXIMUM 0.135 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION DC 1000.0 |
Cross-references
6 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 51MC2-26-10 | 21269 |
| 4300-00064 | 63544 |
| JA1-B3-10-50-2 | 74193 |
| JA1S-B3-A-10-2 | 74193 |
| IEG1-1-52-10.0-91-V | 82647 |
| 51MC2-26-10 | 82647 |