Home / MS parts / NSN 5925-00-561-7328
NSN 5925-00-561-7328  ·  NIIN 005617328  ·  FSC 5925
NO DASHES 5925005617328
In Stock

CIRCUIT BREAKER

Circuit Breakers

Technical characteristics

35 rows

Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.

Technical characteristics from the federal item record
MRCRequirementValue
AAQLBODY STYLE
ADAQBODY LENGTHINCHES NOMINAL 2.187
AFJNFRAGILITY FACTORMODERATELY RUGGED
CPSMINTERNAL TRIP RELEASE CONFIGURATIONALL LOCATIONS SERIES TRIP
CQJXNOMINAL THREAD SIZEINCHES 0.138
CMLPTHREAD QUANTITY PER INCH32
TTQYTERMINAL TYPE AND QUANTITYSCREW 6
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTHINCHES NOMINAL 1.812
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTHINCHES NOMINAL 0.875
FREQFREQUENCY IN HERTZ400.0
MATTMATERIALCASE PLASTIC
AJWXMOUNTING SURFACE TO TERMINAL END DISTANCEINCHES NOMINAL 2.234
AKPXPOLE QUANTITY3
APNQARC QUENCHING METHODAIR
AXHRMOUNTING FACILITY TYPE AND QUANTITYTHREADED HOLE(S) 6
BBRGSTORAGE TYPEGENERAL PURPOSE WAREHOUSE
CPLMMAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLEALL LOCATIONS AMPERES AC 100.0 AND AMPERES DC 100.0
CPRFOPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTSALL LOCATIONS AC 120.0 AND DC 30.000
CPRGMAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPSALL LOCATIONS AC 3500.0 AND DC 6000.0
CPRHCIRCUIT PROTECTION TYPEALL LOCATIONS OVERCURRENT
CPRJTRIP RELEASE METHODALL LOCATIONS MAGNETIC
CPRLTRIP RELEASE CHARACTERISTICALL LOCATIONS TIME DELAY
CPRRMAIN CONTACT TRIPPING MECHANISM TYPETRIP FREE
CPRTMANUAL ACTUATOR TYPE AND QUANTITYPUSH-PULL 3
CPRWACTUATOR FUNCTIONRESET
CPRXACTUATOR POSITION DESIGNATIONAT EACH POLE
CPRYEXTERNAL ACTUATOR LINKAGE ARRANGEMENTONE, TWO, AND THREE LINKED
ADATBODY WIDTHINCHES NOMINAL 2.594
CPRNULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT138.0
CPRQRESET METHODMANUAL
CQXFINCLOSURE PROTECTION TYPE FOR WHICH DESIGNEDGENERAL PURPOSE
AEBQCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTHINCHES NOMINAL 0.875
CQWNTRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENTALL LOCATIONS MINIMUM AT 200 PCT 15.000 AND MAXIMUM AT 200 PCT 65.000
AEBPCENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTHINCHES NOMINAL 1.437
THSDTHREAD SERIES DESIGNATORUNIFIED NATIONAL COARSE (UNC)

Cross-references

4 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.

Manufacturer cross-reference part numbers and CAGE codes
Manufacturer part numberCAGE
132717E388536024
MP944A76374
940-006-10081640
210-513-900599193