NSN 5925-00-798-5229 · NIIN 007985229 · FSC 5925
NO DASHES 5925007985229
In Stock
CIRCUIT BREAKER
Circuit Breakers
Technical characteristics
16 rows
Straight from the federal item record. Entries the record leaves empty are shown empty — nothing is filled in on its behalf.
| MRC | Requirement | Value |
|---|---|---|
| TTQY | TERMINAL TYPE AND QUANTITY | SCREW 3 |
| CPRL | TRIP RELEASE CHARACTERISTIC | SINGLE LOCATION TIME DELAY |
| CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 138.0 |
| CPRQ | RESET METHOD | AUTOMATIC |
| MATT | MATERIAL | CASE PLASTIC |
| CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | SINGLE LOCATION MINIMUM AT 200 PCT 10.000 AND MAXIMUM AT 200 PCT 200.000 |
| CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | EXPLOSION RESISTANT |
| CPRH | CIRCUIT PROTECTION TYPE | SINGLE LOCATION OVERCURRENT |
| CPRJ | TRIP RELEASE METHOD | SINGLE LOCATION THERMAL |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | UNTHREADED HOLE(S) 2 |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| AKPX | POLE QUANTITY | 1 |
| CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | SINGLE LOCATION AMPERES AC 200.0 AND AMPERES DC 200.0 |
| CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | SINGLE LOCATION AC 120.0 AND DC 25.0 |
| CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | SINGLE LOCATION AC 4000.0 |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | INCHES NOMINAL 0.203 |
Cross-references
3 manufacturer part numbers on file for this NSN — each shown against the CAGE code it belongs to.
| Manufacturer part number | CAGE |
|---|---|
| 7236-2-200 | 82647 |
| D7236-2-200 | 82647 |
| 62A100C3011 | 10001 |
Supersedes
This item replaces cancelled NIIN 007168292. An older drawing citing one of those numbers resolves here.